Domestic Reverse Osmosis Membrane Elements Naming Rules

 

 

HatChee Domestic Reverse Osmosis Membrane Elements Performance Quick Check

 

TYPE

 

 

MODEL NO.

 

STABLE REJECTION

(% )

 

 

AVERAGE FLOW

GPD (m3/d)

TESTING CONDITIONS

TESTING PRESSURE

psi(MPa)

CONCENTRATION OF TESTING SOLUTIONS

NaCl(ppm)

RECOVERY RATE

(% )

Domestic RO Membrane Element

HC-1812-75G

98.0

75(0.28)

80(0.5)

250

35

HC-2012-100G

98.0

100(0.38)

HC-2012-150G

98.0

150(0.57)

HC-2012-200G

97.0

200(0.76)

HC-3013-400G

98.0

400(1.52)

100(0.7)

250

50

HC-3013-500G

95.0

500(1.9)

HC-3013-600G

95.0

600(2.28)

HC-3013-800G

95.0

800(3.04)

 

HatChee Domestic Reverse Osmosis Membrane Elements Product Dimension

 

 

Model

A/mm(inch)

B/mm(inch)

C/mm(inch)

D1/mm(inch)

D2/mm(inch)

HC-1812-75G

298 (11.73)

46 (1.81)

17 (0.67)

21 (0.83)

21 (0.83)

HC-2012-100G

298 (11.73)

48 (1.89)

17 (0.67)

21 (0.83)

21 (0.83)

HC-2012-150G

298 (11.73)

48 (1.89)

17 (0.67)

21 (0.83)

21 (0.83)

HC-2012-200G

298 (11.73)

48 (1.89)

17 (0.67)

21 (0.83)

21 (0.83)

HC-3013-400G

333 (13.11)

67.8 (2.67)

17 (0.67)

21 (0.83)

21 (0.83)

HC-3013-500G

333 (13.11)

67.8 (2.67)

17 (0.67)

21 (0.83)

21 (0.83)

HC-3013-600G

333 (13.11)

67.8 (2.67)

17 (0.67)

21 (0.83)

21 (0.83)

HC-3013-800G

333 (13.11)

67.8 (2.67)

17 (0.67)

21 (0.83)

21 (0.83)

 

HatChee Domestic Reverse Osmosis Membrane Elements Product Detailed Data

 

75G,100G,150G,200G membranes are designed for small water supply system such as house pure water machines and small pure water systems of hospitals and laboratories.

 

400G,500G,600G,800G membranes are designed for medium size commercial application, they are the core parts of commercial water machines and pure water systems which are widely used at hospital, school, factory and laboratory.

The membrane is suitable for source water with salinity below 1000 ppm(If the feed water quality is bad. We can offer the membrane which is suitable for source water with salinity below 3000ppm).The membranes can be used for salt rejection treatment of all kinds of below the surface water, groundwater, tap water and municipal water. The membranes are mainly used in pure water, boiler feed water, food processing, pharmaceutical manufacturing industries and many other kinds of fields.

 

 

Model

HC-1812-75G

HC-2012-100G

Performance

Stable salt rejection%

98

98

Minimum salt rejection %

95

95

Average permeate flow GPD(L/d)

75(281)

100(380)

Model

HC-2012-150G

HC-2012-200G

Performance

Stable salt rejection%

98

97

Minimum salt rejection %

95

95

Average permeate flow GPD(L/d)

150(567.75)

200(760)

Testing condition

Testing pressure

80psi(0.5Mpa)

Testing temperature

25℃

Concentration of testing solution (NaCl)

250ppm

PH value of testing solution

6.5-7.5

Recovery rate of single membrane element

35

Maximum operating condition

Max operating pressure

300psi(2.0Mpa)

Max feed water temperature

45℃

Max SDI of feed water

5

Max concentration of free chlorine

<0.1mg/l

PH value range of continual feed water

3~10

PH value range of income water when chemical cleaning

2~11

The maximum pressure drop of single membrane

10psi(0.07Mpa)

 

 

Model

HC-3013-400G

HC-3013-500G

Performance

Stable salt rejection%

98

95

Minimum salt rejection %

95

93

Average permeate flow GPD(L/d)

400(1512)

500(1890)

Model

HC-3013-600G

HC-3013-800G

Performance

Stable salt rejection%

95

95

Minimum salt rejection %

93

93

Average permeate flow GPD(L/d)

600(2270)

800(3030)

Testing condition

Testing pressure

100psi(0.7Mpa)

Testing temperature

25℃

Concentration of testing solution (NaCl)

250ppm

PH value of testing solution

6.5-7.5

Recovery rate of single membrane element

50

Maximum operating condition

Max operating pressure

300psi(2.0Mpa)

Max feed water temperature

45℃

Max SDI of feed water

5

Max concentration of free chlorine

<0.1mg/l

PH value range of continual feed water

3~10

PH value range of income water when chemical cleaning

2~11

The maximum pressure drop of single membrane

10psi(0.07Mpa)

 

Related Information

1.The produced water amount listed in the table is an average value, compare with the standard value, the difference of the minimum amount of water produced by a single membrane does not exceed ± 15%. 

2.All wet membrane undergo rigorous factory inspection, and use specific protective solution and vacuum-packed, then stored in strong cartons. In order to prevent growth of microorganisms during short-term storage, transport and the system standby, we recommend preparation protective solution by RO membrane produced water, then immerse membrane.

3.When new membranes run, the produced water of at least the first hour has to be discharged out.

 

Description: 

1. The safety and suitability of the product is subject to your application intent, please make your decision carefully.

2. The record of the contents will be modified according to the actual product design, if there are any changes, we will not release further notice.

 

 

Packaging

Inquiry Now

Product Name:Residential RO Membrane

Hot products

Top footer
Contact usClose

Company: Tianjin Justin Technology Co.,Ltd

Contact: Justin

Tel: +86 13312099288

Phone: +86 13312099288

E-mail: info@justintec.cn

Address: Qudian Industrial Zone, Beichen District, Tianjin City, China

Scan the qr code关闭
Qr code